Part Number
Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , CURRENT
Definition:
AN ITEM CONSISTING OF ONE OR MORE WINDINGS, DESIGNED TO BE PLACED NEAR OR CONNECTED IN SERIES WITH AN ALTERNATING CURRENT POWER LINE TO MEASURE THE CURRENT PASSING THROUGH THE LINE BY MEANS OF A METER; OR TO CONTROL THE CURRENT PASSING THROUGH THE LINE BY MEANS OF A CONTROL DEVICE. EXCLUDES TRANSFORMER, POWER, CURRENT REGULATING.
CAGE Information
Code | Company |
---|---|
13483 | PRECISION ELECTRONICS INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AGAV | END ITEM IDENTIFICATION | E-3A AWACS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
ABTB | MOUNTING HOLE DIAMETER | 0.220 INCHES NOMINAL SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.820 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.820 INCHES NOMINAL |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.260 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 1ST GROUP |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.260 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |